Tiguan hybrid coolant plus AC problem

August 12, 2025
Tiguan hybrid coolant plus AC problem The expensive heat exchanger was tested and proved to be faulty before it was replaced
Share:

The Autobiz Helpline was contacted by a member garage about a Volkswagen Tiguan 1.4 eHybrid. The Tiguan was booked into the workshop for two problems. The first problem was that the hybrid system had flagged an error P26B1 (Coolant Bypass Valve Stuck Closed). On investigation, it was evident that the hybrid cooling system was very low on coolant.


The technician tried to locate a leak on the hybrid system, but no leaks were evident. These types of leaks can be very difficult to trace. Autofrontal was checked to investigate the fault code, but there were no results on this Tiguan PHEV.

Checking on known issues with low coolant on these models came up with a possible culprit, the heat exchanger on these Tiguans is known to leak internally.

The second problem was that the climate control was inefficient. The refrigerant was removed, and found to be significantly low. Due to the high cost of a replacement heat exchanger, a test plan was needed to prove that it was leaking.

After calling the Helpline for advice, we came up with a different approach to test this issue. We asked for the climate system to be refilled with refrigerant, and explained that there are special precautions to take when filling these systems. You are required to open the valves using a scan tool, to ensure the whole system is filled. This is done before any draining. Vacuum for filling is done on systems that utilize a heat pump.

Once the process is completed, open the coolant expansion cap on the hybrid cooling system. Using a refrigerant leak detection tool, check for the presence of refrigerant.

As this cap was being removed, the technician observed the system was pressurised, even though it had not been run that day. The scan tool showed an extremely high concentration of refrigerant present. This proved without a doubt that the heat exchanger was leaking between the coolant and refrigerant circuits.

This problem will be the same on many models using the same heat pump climate/ battery thermal management system.

To see or download this article click here.

There are lots more Tech Tips to view, and they are all searchable, on TechTips.ie.

To join the Autobiz Helpline, call 01-905-9500, and then press 2, for further information.

 
Tiguan hybrid coolant plus AC problem
PREVIOUS ARTICLE
Local family motor factor re-brands as NAPA Auto Parts Dundalk
NEXT ARTICLE
€6,000 raised in Climb4Cancer

More from AFTERMARKET

Ford announces universal EV platform and major investment programme

Ford announces universal EV platform and major investment programme

icon Ford in the USA has announced...
NAPA Auto Parts opens new store in Mullingar

NAPA Auto Parts opens new store in Mullingar

icon NAPA Auto Parts has continued...
New Premier Hand Tool Trays from Sealey

New Premier Hand Tool Trays from Sealey

icon Sealey is encouraging technici...
Bosch spark plugs – the right choice for hybrid models 

Bosch spark plugs – the right choice for hybrid models 

icon Hybrids are now one of the mos...
Ring announces new Head of ACE Global Product Management

Ring announces new Head of ACE Global Product Management

icon Stuart Bullen has recently bee...
€6,000 raised in Climb4Cancer

€6,000 raised in Climb4Cancer

icon Earlier this Summer, a dedicat...

More from AUTOBIZ